Table 3-13: Remote Serial Operation

Command

ASCII

HEX

Description

%p F0h

Initiates print function. Print restrictions (P200 – P233) will be adhered
to.

Print

W<CR>
or
P<CR>

57h, 0Dh

Initiates print function. Print restrictions (P200-P212) will be
adhered to. Requires both hex values, 57h followed by 0Dh.

Select

%s

F3h

Performs a parameter or mode select operation.

Tare %t

F4h

Initiates tare function. Tare restrictions (P161 - P169) will be adhered
to.

Units

%u

F5h

Toggles between displayed units of measure.

%z

FAh

Initiates zero function. Zero restrictions (P118) will be adhered to.

Zero

Z<CR> 5Ah,

0Dh

Initiates zero function. Zero restrictions (P118) will be adhered to.
Requires both hex values, 5Ah followed by 0Dh.

Piece Weight Entry

%9

B9h

Allows a piece weight to be entered serially. For example, 0.10%9 will
enter a piece weight of 0.10.

Enter %e

E5h

Enters preceding data into selected register. Also toggles through
selections in Setup Mode.

<CR> is a carriage return, decimal value 013, hex value 0Dh.

DISPLAY CAPTURE UTILITY

The Display Capture Utility sends the current display information out of the one of the available
comm ports when the one of the two extended ASCII character represented by decimal 149 (hex:
95h) or decimal 150 (hex: 96h) are received through the comm port. The previous characeters
can be used when the comm. port is set to 8 data bits. For 7 data bits comm. port, %[Ctrl-V] or
%[Ctrl-W] can be used to replace 149 or 150 respectively. Upon receiving decimal 149, the
Display Capture Utility sends the current display information out of comm. port 1. Upon receiving
decimal 150, the Display Capture Utility sends the current display information out of comm. port
2. Entering a decimal 149 from a computer keyboard can be accomplished by turning on the Num
Lock and holding down the ALT key while typing the desired decimal number on the keyboard
keypad (for example, <Alt>149).



The Display Capture Utility must have NTEP (P440) disabled in order to function.

Example #1
The scale is in the weigh mode with the gross weight displayed (for example, 15.00).

Input: The extended ASCII character represented by decimal 149 (hex: 95h) is received through
any comm port.

Output: "15.00 lb Gross " is sent out comm port 1.

Example #2
The scale is in setup at P110 Full Scale.

Input: The extended ASCII character represented by decimal 150 (hex: 96h) is received through
any comm. port

Output: "P110 F.S. 100.00 " is sent out comm port 2.