DISPLAY READS Enter ~ Load ~ xx.xx

11. Enter 100 with the [PRINT] and [UNITS] keys.

DISPLAY READS 100

12. Press [TARE] to establish span.

DISPLAY READS 100.00

13. Pause for motion delay.

DISPLAY READS Cal ~ Good? ~ 100.00

14. Press [TARE] to accept calibration.

DISPLAY READS Enter ~ =Stor

15. Press [TARE] to save calibration.

DISPLAY READS Enter ~ =End

16. Press [TARE] to exit calibration.

DISPLAY READS 100.00

17. Remove the calibration weight.

DISPLAY READS 0.00

Reset Calibration Gain Factors Example (375):

1. Press

100 [SELECT].

DISPLAY READS Setup

2. Press

54321 [SAMPLE/Enter].

DISPLAY READS Fast ~ Cal~First ~ Zero? ~ xx.xx

3. Remove any load on the scale.

DISPLAY READS First ~ Zero? ~ xx.xx

4. Press

[SAMPLE/Enter] to establish zero.

DISPLAY READS Enter ~ Load? ~ 0.00

5. Place a 100lb test weight on scale.

DISPLAY READS Code03

6. Press

[ZERO].

DISPLAY READS First ~ Zero? ~ -0.26

7. Remove any load on the scale.

DISPLAY READS First ~ Zero? ~ -0.42

8. Press

[SAMPLE/Enter] to establish zero.

DISPLAY READS 0.00

9. Pause for motion delay.

DISPLAY READS Enter ~ Load ~ 0.00

10. Place a 100lb test weight on scale.

DISPLAY READS Enter ~ Load ~ xx.xx

11. Enter 100.

DISPLAY READS 100

12. Press [SAMPLE/Enter] to establish span.

DISPLAY READS 100.00

13. Pause for motion delay.

DISPLAY READS Cal ~ Good? ~ 100.00

14. Press [SAMPLE/Enter] to accept calibration.

DISPLAY READS Enter ~ =Stor