Holtgreven GSE-375 User Manual

Page 56

Advertising
background image

50

3. Press

[TARE] or [SAMPLE/Enter] to access the low tolerance parameter. This parameter

does not have to be changed. Go to step 4 to change the low tolerance or press [SELECT] to
go to the weigh mode or press [TARE] to view the high tolerance, go to step 6.
DISPLAY READS Lo ~ 2

4. Set the low tolerance to a specific value. For example press 1[TARE] or [SAMPLE/Enter] to

set a new low tolerance.
DISPLAY READS Lo ~ 1

5. Press

[TARE] or [SAMPLE/Enter] to access the high tolerance setting.

DISPLAY READS Hi ~ 3

6. Set the high tolerance to a specific value. Press 2[TARE] or [SAMPLE/Enter] to set a new

high tolerance.
DISPLAY READS Hi ~ 2

7. Press

[SELECT] to display the current Gross Weight.

Example (Target Deviation Check-Weighing)

With a system set up to check-weigh ice cream containers, the following settings might be used
to guarantee container weights from 1.98 to 2.04 lbs.:

Parameter Setting

Acceptable Check-weigh
Values

Comments

Target = 10.00

Desired container weight.

Lo Value = 0.5

10.00 - 0.5 = 9.50

Low acceptable range = 9.50 to 10.00

Hi Value = 0.25

10.00 + 0.25 = 10.25

High acceptable range = 10.00 to 10.25

P

P

a

a

r

r

t

t

s

s

C

C

o

o

u

u

n

n

t

t

i

i

n

n

g

g

The counting parameter must be enabled before the quantity mode is available. Refer to page 24
for details on the counting parameter and page 15 to enter the setup mode, make changes and
save the change.

To sample using selectable fixed counts:

1. Press

[SAMPLE/Enter] to perform an auto-tare. The scale prompts to add 10 pieces.

DISPLAY READS Add ~ 10

2. Press

[UNITS] to toggle sample amounts between 5, 10, 20, 50 and 100.

DISPLAY READS Add ~ 20

3. Add the pieces to be sampled and press [SAMPLE/Enter] to sample and display the current

quantity.
DISPLAY READS 20

To sample using variable counts:

1. Press

[SAMPLE/Enter] to perform an auto-tare. The scale prompts to add 10 pieces.

DISPLAY READS Add ~ 10

2. Add pieces, key in desired count (example: 36), then press [SAMPLE/Enter] to sample as 36

pieces and display the current quantity.
DISPLAY READS Add ~ 36

Advertising