Etup, Emote – Holtgreven GSE-375 User Manual

Page 62

Advertising
background image

56

S

ETUP

R

EMOTE

U

NIT

For an Model 370/375 to become a remote display P260 must be set for r-dsp. There are two
styles in which the remote unit will display data received from the master unit. These styles are
display and custom. Choose one of the display styles at P271. Refer to page 57 for details on
display and custom styles.

The parameters in Table 3-15 are available only when P260 is set for r-dsp or Hub. Refer to
Table 3-15 for the available parameters and their descriptions.

Table 3-15: Remote Display Setup Parameters

Parameter
Setting

Displayed
Name

Description

Type/choices
(*=Default)

P261.01

R-port

Choose the comm port in which the remote display (slave) will
communicate with the master device.

1*, 2, None

P270.00

T-out

Determines whether the remote display (slave) will show a message
when connection is lost.

Enable /
Disable*

P271.00

Style

Set to display or custom. When set to display the remote will echo the
display of the master unit. When set to custom the remote receives a
custom format from the master unit. In custom mode the transmit may
be send continuous or on demand.

Display* /
Custom

P272.00

Addr

Set address for remote display. Only present if P271 is set for custom. None*,

1-255

P273.01

T-use

Determines where transmits sent out the comm. port from the master
or control unit that is connected to the remote or hub are redirected to.
Should not be set to the same port as P261 unless transmit wire is
being used to connect to a printer connected to the remote unit (In this
case the keypad cannot be used to talk to the master or control unit).

None*, Port 1,
Port 2

P274.02

Start

Set the start character for the remote display. Choices are 0 – 255.
Default value is 2 (STX). The choice must match the start character in
P291 on the master display. Avoid using values of 17 or 19 when
using software flow control. The values of 17 and 19 are Xon and Xoff
codes and could cause conflict.

Numeric Entry:
0 to 255
2*

P275.03

End

Set the end character for the remote display. Choices are 0 – 255.
Default value is 3 (ETX). The choice must match the end character in
P292 on the master display. Avoid using values of 17 or 19 when
using software flow control. The values of 17 and 19 are Xon and Xoff
codes and could cause conflict.

Numeric Entry:
0 to 255
3*

P276.01

Rptin

Allow or disallow data received from the remote display’s (slave)
communication port to be sent to the master.

Enable* /
Disable

P277.01

R-start

Enables or disables the use of the [START] key on the master unit.
When this parameter is enabled and the key is pressed, a start key
command will be recognized by the master unit. The Tx, Rx and GND
line must be connected between the COMM Ports of the master and
remote unit. If this parameter is disabled the [START] key will have
no effect on the master unit.

Enable* /
Disable

P278.01 R-stop

Enables or disables the use of the [STOP] key on the master unit.
When this parameter is enabled and the key is pressed, a stop key
command will be recognized by the master unit. The Tx, Rx and GND
line must be connected between the COMM Ports of the master and
remote unit. If this parameter is disabled the [STOP] key will have no
effect on the master unit.

Enable* /
Disable

P280.01

Zero

Enables or disables the use of the [ZERO] key on the master unit.
When this parameter is enabled and the key is pressed, a Zero key
command will be recognized by the master unit. The Tx, Rx and GND
line must be connected between the COMM Ports of the master and
remote unit. If this parameter is disabled the [ZERO] key will have no
effect on the master unit.

Enable* /
Disable

P281.01

Units

Enables or disables the use of the [UNITS] key on the master unit.
When this parameter is enabled and the key is pressed, a Units key
command will be recognized by the master unit. The Tx, Rx and GND
line must be connected between the COMM Ports of the master and
remote unit. If this parameter is disabled the [UNITS] key will have no
effect on the master unit.

Enable* /
Disable

P282.01

Select

Enables or disables the use of the [SELECT] key on the master unit.
When this parameter is enabled and the key is pressed, a Select key
command will be recognized by the master unit. The Tx, Rx and GND

Enable* /
Disable