Holtgreven GSE-375 User Manual

Page 34

Advertising
background image

28

P502 Time/Date

(toggle)

Enables or disables the time and date feature. If enabled the time and date will be accessible
from the weigh mode with the [SELECT] key. The weight will continue to be updated when
viewing the time or date. The time will be formatted as defined by P503 and the date will be
formatted as defined by P504. See page 52 for instructions on how to change the time and/or
date.

P503 Hours

(toggle)

Determines the TIME format style, 12 hour or 24 hour. If in 12-hour mode the right most decimal
point on the display will become the PM indicator. Note: The time must be entered as military
time. If the mode is set for 12-hour, the time will be converted to a 12-hour clock.

P504

Style (toggle)

Determines the DATE format style, U.S.A. or Int'l. If set for U.S.A, the date will resemble
01/26/01. If set for international, the date will resemble 26/01/01.

P505

Time/Date Select (toggle)

Enables or disables the editing of time and date the weigh mode.

P800

Remote Key 1 Operation (Selection)

A physical Remote Key closure

does not exist and is not functional on the Model 370/375. The

remote key choice for activation within a setpoint will not work.

P1000 Custom Transmit 1
A custom transmit is a user-defined string of data that can be sent to the serial port. Parameter
P1000 is the beginning of the custom transmit table for transmit 1and must be enabled for
transmit by selecting cust” at P213. Parameters use three bytes of memory; ASCII characters
and control codes use one byte. See P60001 for available memory. The custom transmit cannot
be viewed or altered from the Model 370/375. A custom transmit must be entered via the serial
port. See Custom Transmit Setup on page 31 for details on designing and loading a custom
transmit.

P2000 Custom Transmit 2
A custom transmit is a user-defined string of data that can be sent to the serial port. Parameter
P2000 is the beginning of the custom transmit table for transmit 2 and must be enabled for
transmit by selecting cust” at P230. Parameters use three bytes of memory; ASCII characters
and control codes use one byte. See P60001 for available memory. The custom transmit cannot
be viewed or altered from the Model 370/375. A custom transmit must be entered via the serial
port. See Custom Transmit Setup on page 31 for details on designing and loading a custom
transmit.

P5000 Target Key (Toggle)
Although the target key is not physically on the keypad, a target value can be entered by sending
a %<CTRL A> using a serial device such as a computer. P5000 must be enabled and a setpoint
that uses a target value must be enabled before the target can be entered in this manner.

P5002 Stop Key (Toggle)
Although the stop key is not physically on the keypad, you can stop a setpoint remotely by
sending a %<CTRL F> using a serial device such as a computer. P5002 and a setpoint must be
enabled before the stop function will operate in this manner.

P5003 Start Key (Toggle)
Although the start key is not physically on the keypad, you can start a setpoint remotely by
sending a %<CTRL E> using a serial device such as a computer. P5003 and a setpoint must be
enabled before the start function will operate in this manner.

Advertising
This manual is related to the following products: