91

Chapter 6 Functions for Reading Operation

6

6.2.4 Multi-label read mode 3 (Multi 3)

•

Multi-label read mode 3 allows the BL-600 Series to continuously read one of
each of the 4 bar code types, “Code 1” to “Code 4”, as specified in the [[Code
setup]] screen of the setup software

(

➮

See page 49.)

during one trigger input

signal.

*

If three types are specified in the [[Code setup]] screen, the BL-600 Series
reads three bar codes. If two types are specified, it reads two bar codes.

•

Even if several bar codes (4 max.) exist in the field of the laser beam, the BL-
600 Series can simultaneously read all the bar codes, provided the data of all
the bar codes is different.

The BL-600 Series sends all the read data at one time in the order of “Code 1” to
“Code 4” after the trigger input turns off.

■ Timing diagram

*

The BL-600 Series continuously reads bar codes in the following periods.

•

For a “Level signal” trigger

➮ See page 86.

:

During the trigger input signal

•

For a “One-shot” trigger

➮ See page 87.

:

During the preset input time

*

The OK signal turns on if the BL-600 Series reads all the bar codes specified for
“Code 1” to “Code 4”.(Comparison to the preset data is not performed.)
The NG output turns on if the BL-600 Series fails to read at least one bar code.

■ Data format
The read data is sent to the personal computer in the following format.

*

Each data packet is separated by a comma (, : 2CH) (intermediate delimiter).

*

If the reading fails for any one of the Codes 1 to 4, or the corresponding bar
code does not exist, an “ERROR”

(

➮ See page 112 for the reading error codes.)

is sent

instead of the read data.

➮ See page 113 for “header string” and “delimiter”.

OK

Trigger input

Bar Code

Laser beams

Communication time

OK/NG output

Code 1 Code 2 Code 3 Code 4

Code 1

Code 2

Code 3

Code 4

NG

<Succeed to read>

<Fail to read>

Header

Data read
from Code

1

Data read
from Code

2

Data read
from Code

3

Data read
from Code

4

,

,

,

Delimiter