5 wiring the rs-422a – KEYENCE BL-600 Series User Manual

Page 33

Advertising
background image

Chapter 3 Connection and Installation

23

3

SYSMAC-CV Series
Connection with CV500-LK201(Port 1)

Connection with CV500-LK201 (Port 2),

CV500,
CV1000,
CVM1

3.1.5 Wiring the RS-422A

Note 1: The cable can be extended to within 1.2 km.

Note 2: Turn ON the terminators (BL-U1/external unit terminal resistance: 100

Ω).

➮ See page 17.

Connect the BL-U1 to other devices with the following wiring.

Connecting a general RS-422A unit
Use the same wiring when connecting the BL-U1 to the BL-U1*.

Connecting the MELSEC-A Series
Connecting with AJ71(U)C24(-S

),

AJ71QC24-R4,
A0J2-C214-S1,
A1SJ71(U)C24-R4

2

Link unit

SD

RD

RS

CS

SG

3

4

5

7

2

1

1

BL-U1*

SD

FG

FG

RD

RS

CS

SG

3

4

5

7

D-sub 25-pin (male)
M2.6 screw

D-sub 25-pin (male)
M2.6 screw

2

PLC

SD

RD

RS

CS

SG

3

4

5

9

2

1

1

BL-U1*

SD

FG

FG

RD

RS

CS

SG

3

4

5

7

D-sub 25-pin (male)
M2.6 screw

D-sub 9-pin (male)
M2.6 screw

* KEYENCE option OP-22149 (1.5 m) or

commercially available cross cable can be
used.

SDA

SG

BL-U1*

SDB

RDA

RDB

RD + (RDA)

SG

External unit

BL-U1*

RD – (RDB)

SD + (SDA)

SD – (SDB)

Twisted pair cable

SDA

SG

BL-U1*

SDB

RDA

RDB

RDA

SG

Link unit

RDB

SDA

SDB

Twisted pair cable

Advertising