Chapter 3 Connection and Installation

19

3

Connecting trigger input

The trigger input allows the BL-600 Series to start reading bar codes (turn on the
laser beam).
The trigger input is turned ON when 8.5 to 30 V DC input is activated between the
trigger input terminals.
The BL-U1’s power supply terminals for the sensor can be used as the power
supply input for the sensor.

Connection to a photoelectric sensor manufactured by KEYENCE

Connecting the OK/NG output

The OK/NG output is used to differentiate between acceptable and unacceptable
results based on a comparison with preset data

(

➮ See pages 101.). It can also be

used to indicate whether or not the BL-600 Series successfully reads bar codes
when there is no preset data entered.
The OK/NG output is an NPN open-collector output.

Connection to a programmable logic controller (PLC) manufactured by

KEYENCE

TIM

+12 V OUT–

8.5 to 30 V DC

+

+

Contact or
solid-state

+12 V OUT–

TIM

Photoelectric sensor

Brown (Red)

Black (White)

Blue (Black)

COM

OK

NG

Load

Load

+

*Rated load: 30 V DC max. (100 mA)

0001

0000

C

COM OK NG

+

PLC