Chapter 4 Setup Software

58

4

2) The “Send/Receive settings (BL)” screen appears.

To send the updated settings to the BL-600 Series
Select “Use N-400” and enter the ID number of the desired BL-600
Series. Then, click the [Send settings] button.

To read the settings of the BL-600 Series
Select “Use N-400” and enter the ID number of the desired BL-600
Series. Then, click the [Read BL settings] button.

Note: If improper settings are sent to the BL-600 Series, communication with the
N-400 is disabled.
To avoid problems, read the settings of the BL-600 Series first, then change only
the necessary items.

4. Sending/reading result

The following messages appear to indicate whether the sending/receiving
operation was successful or whether it failed.

If the operation failed, check the following points:

Check that the N-400 displays “SO (50)”.

Check that the settings for the [[Com port]] are specified as described in step 2.

Check that the N-400 and special power supply unit are turned on.

Check that the multi-drop link between the N-400 and the BL-600 Series is
properly established.

5. Canceling the “communication waiting status”.

Press the TEST switch of the N-400 once. The “communication waiting status”
is canceled.

Click the [Cancel] button to return
to the previous screen.

Sending succeeded

Sending failed

Reading succeeded

Reading failed

Press the TEST switch once.