Note: It is only possible to send/receive settings with a BL-600 Series that has
already established a multi-drop link with the N-400.

1. Set the N-400 to “setting data send/receive waiting status”.

1) Press the N-400 TEST switch for 5 seconds.

2) Communication can begin when “SO (50)” is displayed.

2. Check or change the communication parameter settings of the personal com-

puter.

1) Click on [[Com port]].

2) Set each parameter as shown below.
3) Select an appropriate RS-232C port.
4) When the settings are complete, click the [OK] button.

3. Sending/receive settings to/from the BL-600 Series via the N-400.

1) Click on [[Transfer]].

Baud rate: 9600 bits/s

Stop bit length: 1 bit

Parity: Even

Data length: 7 bits

Select an appropriate
RS-232C port.

Click the [OK] button to return
to the previous screen.

Press the TEST switch
for 5 seconds.