KEYENCE BL-600 Series User Manual

Page 60

Advertising
background image

Chapter 4 Setup Software

50

4

Note 1: For “ITF”, “(Industrial) 2of5”, and “COOP 2of5”, be sure to fix the number of
digits according to the bar code actually used. Otherwise, some digits may be
skipped (not read) without recognition.

Example

To fix the number of digits to “8”
Specify “Max=” as “8” and “Min=” as “8”.

Note 2: It is recommended to fix the number of digits for “Codabar”. Some digits
may be skipped depending on the print condition or the position of the bar code
reader.

Note 3: When reading only one type of bar code, specify it in “Code 1” and leave
the other boxes as “None”. This decreases the possibility of misreading.

2. Set the items for [Detail].

When the [Detail] button of “Code 1” through “Code 4” is clicked, the “Bar code
detail setup” screen appears.
Specify each item.
The items vary depending on the specified type of bar code.

For “CODE39”

“Send start/stop character (*)”
If “Send start/stop character (*)” is set, the BL-600 Series adds an “*”
(asterisk) to the read data and sends it to the PC.

“Inspect check-digit [Modulus 43]”
If “Inspect check-digit [Modulus 43]” is set, the option “Send check-digit”
is activated (displayed in black).

“Send check-digit”
If “Send check-digit” is set, the BL-600 Series sends the read data with
the check digit to the PC.

For “ITF”

“Inspect check-digit [Modulus10/Weight3]”
If “Inspect check-digit [Modulus10/Weight3]” is set, the option “Send
check-digit” is activated (displayed in black).

“Send check-digit”
If “Send check-digit” is set, the BL-600 Series sends the read data with
the check digit to the PC.

Click the [OK] button to return
to the [[Code setup]] screen.

“Send check-digit”

“Inspect check-digit
[Modulus 43]”

“Send start/stop character (*)”

Click the [OK] button to return
to the [[Code setup]] screen.

“Send check-digit”

“Inspect check-digit
[Modulus10/Weight3]”

Advertising