Chapter 3 Connection and Installation

25

3

3.2

Connecting the BL-U2/N-42 and Wiring

This section describes the connection and wiring of the BL-600 Series and periph-
eral devices when the special power supply unit BL-U2 or N-42 is used.

3.2.1 Connecting the BL-U2/N-42, AC power supply, and BL-600 Series

1. Connect the 24 V DC power supply to the power supply terminals of the BL-U2

or N-42.

BL-U2

N-42

Power supply terminals

Power supply terminals

Make sure that the power supply provides 24 V DC. If the power supply
output is not 24 V DC, it can damage the unit.

Note: If the power supply is UL rated, it must provide Class 2 output.

2. Connect the BL-600 Series to the READER port of the BL-U2 or N-42.

BL-U2

N-42

POWER

SD

RD

READER

RS-232C

TER

MIN

AT

OR

ON

OF

F

POWER

SD

RD

READER

Power supply
terminals

Power supply
terminals

+

+

-

2 4 V D C

24V DC IN

+

+

-

2 4 V D C

24V DC IN

N.C.

N.C.

N.C.

CAUTION

BL-600 Series

Connector

READER port

BL-600 Series

Connector

READER port

Advertising