Chapter 7 Serial Communication

7

Explanation of direct control commands

The following describe direct control commands in details.

Trigger on

Command: LON
Response: None

Trigger off

Command: LOFF
Response: None

Even when the read operation is controlled with these commands, the BL-600
performs the same operation as with the trigger input.

➮ See pages 86 to 93.

“Trigger input: on” corresponds to LON, and “trigger input: off” corresponds to
LOFF.

The BL-600 Series starts reading bar codes on receipt of LON and stops
reading on receipt of LOFF.
If the bar codes are properly read and the read data is sent back, you do not
need to send LOFF.

The command characters can be freely changed (within 8 characters).

Reading rate check

Command: TEST1
Response: None

Tact check

Command: TEST2
Response: None

Resetting test

Command: QUIT
Response: None

After using the test mode, be sure to reset it.

Turning the OK output on

Command: OKON
Response: OK

Turning the NG output on

Command: NGON
Response: OK

Turning the OK/NG outputs off

Command: ALLOFF
Response: OK

Read operation control

This command specifies the data read timing.

Test mode control

Starts or quits the test mode.

OK/NG output control

Directly turns on/off the OK/NG output.
This enables you to easily check wiring.