KEYENCE BL-600 Series User Manual

Page 138

Advertising
background image

Chapter 7 Serial Communication

128

7

Utility Setting (Stability LED, OK/NG output duration, Preset data for

compare)

To register the preset data, send the following command.

Example

Register “ABC123” as preset data.

WP68ABC123

Tips

Function

Command being

Response

Description

Error

sent

code

Change

WP09n

OK

n=0: Disable

Confirm

RP09

09n

1: Enable

Change

WP40nnn

OK

nnn= 001 to 255

Confirm

RP40

40nnn

(by 10 ms step)

Change

WP68aaa...

OK

aaa...= Preset data

Confirm

RP68

68aaa...

(Up to 32 characters)

* For CODE128,

see P.136 to 137.

* To delete the

preset data, send
WP68.

Change

WP0Mn

OK

Confirm

RP0M

0Mn

Change

WP0Rn

OK

n= 0: OFF

Confirm

RP0R

0Rn

1: On

Change

WP85n

OK

n = 0: Disable output

Confirm

RP85

n

1: Enable output

Change

WP93nnn

OK

nnn= 000 to 255

Confirm

RP93

93nnn

Indication of
Stability LED

Setting OK/NG
output duration

Registration of
preset data for
compare

Scaling factor for
the quiet zone

Reading a
reversed bar code

Outputting the
test mode result

n = 0: 4x

1: 5x
2: 6x
3: 7x
4: 8x
5: 9x
6: 10x
7: 11x

Changing the
decoding match
count

00, 02,
05, 07,
14

00, 02,
05, 09,
14

00, 02,
05, 12,
13, 14,
17, 18

00, 02,
05, 07,
14