Chapter 4 Setup Software

64

4

Command buttons

Click [Quit] to return to
the previous screen.

3. Enter the serial communication command in the “Send Command” field

(

➮ See

pages 114 to 128.)

and press the [ENTER] key on the keyboard. Now, commands

can be sent from a personal computer to the BL-600 Series.

*

Use only uppercase characters for the commands.

•

Command transmission with the command buttons

Clicking the command buttons on the right side of the screen allows the
following commands to be sent to the BL-600 Series.

[TEST1] button: Activates the reading rate check mode.
[TEST2] button: Activates the tact check mode.
[QUIT] button: Quits the test mode.
[LON] button: Starts reading.
[LOFF] button: Quits reading.

4. Checking the history of sent commands

Clicking of the “Send Command” field displays the history of the sent com-
mands (up to 100 commands).

[Quit] button