KEYENCE BL-600 Series User Manual
Page 74
Chapter 4 Setup Software
64
4
Command buttons
Click [Quit] to return to
the previous screen.
3. Enter the serial communication command in the “Send Command” field
(
➮ See
pages 114 to 128.)
and press the [ENTER] key on the keyboard. Now, commands
can be sent from a personal computer to the BL-600 Series.
*
Use only uppercase characters for the commands.
•
Command transmission with the command buttons
Clicking the command buttons on the right side of the screen allows the
following commands to be sent to the BL-600 Series.
[TEST1] button: Activates the reading rate check mode.
[TEST2] button: Activates the tact check mode.
[QUIT] button: Quits the test mode.
[LON] button: Starts reading.
[LOFF] button: Quits reading.
4. Checking the history of sent commands
Clicking of the “Send Command” field displays the history of the sent com-
mands (up to 100 commands).
[Quit] button