KEYENCE BL-600 Series User Manual

Page 129

Advertising
background image

119

Chapter 7 Serial Communication

7

Response error code

When an incorrect command is sent to set parameters, the BL-600 sends back
data indicating the cause of the error (error code). For the commands correspond-
ing to the error codes, see the error code column given in the table on the following
pages.

Error code

Cause of error

00

Undefined command.

01

Command format is incorrect.

02

Nothing corresponds to the number in the command.

03

“m” value (codes 1 to 4) is other than 0 to 3.

“Bar code type setting command” was not sent first.

See page 120.

04

Sending “No. of readable digits setting command” is invalid for UPC/EAN
code.

05

The number in the command is too long.

06

“hhh...” data is too short.

07

“n” value is not 0 or 1.

08

“n” value is exceeding the setting range.

09

“nnn” or “nn” value is exceeding the setting range.

10

“hhh...” is not specified in HEX (hexadecimal) code.

11

“hhh...=FF” cannot be set.

12

“hhh...” or “aaa...” contains more than the specified number of characters.

13

Characters of “aaa...” are invalid.

14

Data in the EEPROM may be damaged. Perform initial setup.

15

Error in the area storing initial settings.
Settings are automatically initialized.

17

\ is not followed by !, ? or \ in preset data.

See pages 164 and 165.

18

Two !s exist in preset data.

See page 101.

99

The BL-600 may malfunction. Contact KEYENCE.