EVCO EVFTFT818P7U Installer manual User Manual

Page 32

Advertising
background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 32 of 94

During hard blast chilling the device displays the residual blast chilling time, the temperature of the cabinet, the name

of the program (if envisioned) and the time passed from the start of blast chilling.

Operate as indicated to stop the cycle:

6.

Press and hold the START/STOP key 3 s.

The successive parameters establish the following values:

-

parameter r9 establishes the work set-point during the blast chilling hard phase

-

parameter r14 establishes blast chilling hard phase duration.

On expiry of the hard blast chilling phase duration, the device automatically passes to blast chilling.

During blast chilling the device displays the residual blast chilling time, the temperature of the cabinet, the name of

the program (if envisioned) and the time passed from the start of blast chilling.

The successive parameters establish the following values:

-

parameter r1 establishes blast chilling duration

-

parameter r7 establishes the work set-point during blast chilling.

On expiry of the blast chilling duration, the device automatically passes to storage mode and the buzzer is activated

for the time period established with parameter AA.

Press and release a key to silence the buzzer.

During storage the device displays the temperature of the cabinet, the program name (if envisioned) and the duration

of blast chilling.

Parameter r10 establishes the work set-point during storage.

Advertising