EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 77 of 94

Storage LED.

If it is on:

-

storage will be in progress.

If flashing:

-

work set-point modification will be in progress (cabinet temperature).

Blast chilling/deep freezing intensity LED bars (only if parameter F0 is set at 3).

They supply information relative to evaporator fan speed (for example, one bar on corresponds to

speed 1, two bars on correspond to speed 2, three bars on correspond to speed 3, etc.).

Pre-cooling LED.

If it is on:

-

pre-cooling will be in progress and the cabinet temperature will have reached that established

using parameter r12.

If flashing:

-

pre-cooling will be in progress and the cabinet temperature will not have reached that

established using parameter r12.

AUX

Auxiliary LED.

If it is on:

-

the cabinet light will be on

-

needle probe heating will be in progress

-

the UV light will be on.

HACCP

HACCP LED.

If it is on:

-

all information regarding HACCP alarms will not have been displayed.

If flashing:

-

the device will have memorised at least one new HACCP alarm.

°C

Degree Celsius LED.

If it is on:

-

the temperature unit of measurement will be the degree Celsius.

°F

Degree Fahrenheit LED.

If it is on:

-

the temperature unit of measurement will be the degree Fahrenheit.

min

minutes LED.

If it is on:

-

the time unit of measurement will be the minute.

If the ON/STAND-BY key is on, it means that the device will be in the “stand-by” state.