10 compressor operating hours count, 1 display of compressor operating hours – EVCO EVFTFT818P7U Installer manual User Manual

Page 53

Advertising
background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 53 of 94

10

COMPRESSOR OPERATING HOURS COUNT

10.1

Display of compressor operating hours

Operate as follows:

1.

Make sure that the instrument is in the “on” status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the HOME key (1), press and release the MENU key (2) and then press and release the

key repeatedly (3) in order to select the “INTERNAL VALUES”.

4.

Press and release the

key (4) and then repeatedly press and release the

key (5) or the

key (6) to

select “CH”.

Operate as follows to exit the procedure:

5.

Press and release the ESCAPE key or do not operate for 60 s.

To delete the compressor operating hours, see paragraph 10.3 "Restoring the factory settings".