During deep freezing the device displays the temperature of the cabinet, the program name (if envisioned) and the

duration of deep freezing.

Parameter r11 establishes the work set-point during storage.

6.10

Time-controlled soft deep freezing and storage

The time-controlled soft deep freezing and storage cycle is divided into the following three phases:

-

deep freezing soft phase

-

deep freezing

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the

key (1), and then press and release the

key (2): the device will display the

duration of deep freezing and the work set-point during deep-freezing.

4.1

Press and release the MENU key and then press and release the

key or the

key to select the deep

freezing duration and the work set-point during deep freezing.

4.2

Press and release the

key or the

key to modify these values and then the ESCAPE key to memorise them;

these values can also be memorised through parameters r2 and r8.

5.

Press and release the START/STOP key (1): the cycle will be started.