EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 45 of 94

If the UV light is on, it will not be allowed to select or start any operating cycle.

6.16

Heating the needle probe

Operate as follows:

1.

Make sure the device is in the "on" status or storage is in progress and that the door is open, i.e. the door

micro switch is active.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the

key (1), press and release the

key (2) and then press and release the

START/STOP key (3). The device will display the temperature detected by the needle probe and the cabinet

temperature.

Output K6 is activated at maximum for the time established with parameter u8 or until the temperature detected by

the needle probe reaches that established with parameter u7; closing the door, i.e. the deactivation of the door micro

switch input causes heating to be cut-off.

The buzzer is activated for 2 s on conclusion of heating.

6.17

Fish sanification

The fish sanification cycle is divided into the following three phases:

-

blast chilling

-

maintenance

-

storage.

On conclusion of a phase, the device passes automatically to the next.

Operate as indicated to start the cycle:

1.

Make sure the device is in the "on" status.

2.

Make sure that the keyboard is not locked and that no procedure is in progress.

3.

Press and release the

key (1) and then press and release the

key (2): the device will display the blast

chilling end temperature, the work set-point during blast chilling and the duration of maintenance.