EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 69 of 94

LP

0

2

- - - -

2

parity

0 = none (no parity)

1 = odd

2 = even

Par.

Min.

Max.

Unit

Default

Various

E8

0

2

- - - -

2

"keyboard lock" function activation mode

0 = function not enabled

1 = manual with permanent effect (to lock the keyboard,

make sure no procedure is in progress, after which

press and release the ON/STAND-BY key and then

press the highest interactive key on the left; to

unlock the keyboard repeat the procedure)

2 = automatic with permanent effect (on expiry of 60 s

the keybord will automatically lock; to unlock the

keyboard, make sure no procedure is in progress,

after which press and release the ON/STAND-BY key

and then press the highest interactive key on the

left)

E9

0

1

- - - -

1

EVCO splash screen display during passage from the "off"

status to the "stand-by" status and restore of the power

supply.

1 = yes

Notes:

(1)

the unit of measurement depends on parameter P2

(2)

appropriately set the parameters relative to the regulators after modification of parameter P2

(3)

the time established with the parameter is counted also during the "on" status and during the "stand-by" status

(4)

The parameter differential is 2 °C/4 °F

(5)

on device switch-on (or cycle start), if the condenser temperature is already over that established with

parameter C7, parameter C8 will have no effect

(6)

defrosting is only enabled during pre-cooling, on start-up of blast chilling and at the start-up of deep freezing

(in these last two cases on condition that parameter d4 is set at 1) and during storage

(7)

the device memorises the defrosting interval count every 30 minutes; the modification of parameter d0 has

effect from the conclusion of the previous defrosting interval (or the activation of defrosting in manual mode)

(8)

if on activation of defrosting, the previous compressor switched on at from a time shorter than that established

with parameter d15, the compressor will remain on longer for the fraction of time necessary to complete this

time period

(9)

the temperature alarms are only enabled during storage

(10)

during defrosting, pre-dripping, dripping and evaporator fan standstill, the temperature alarms are not enabled,

on condition that they occurred after activation of defrosting. When the door is open, i.e. if the door micro

switch input is active and the parameter i0 is set at values different to 0, the maximum temperature alarm is

not enabled, on condition that occurred after the door was opened

(11)

if parameter P4 is set at 0, during pre-cooling, blast chilling and deep freezing the evaporator fan will be on and

during storing the device will operate as if parameter F2 it were set at 2

(12)

if parameter P5 is set at 0, the condenser fan will function parallel to the compressor