4.1

Press and release the

key or the

key to select these values and press and release the

key or the

key to modify them.

5.

Press and release the START/STOP key (1): the test to verify the correct insertion of the needle probe will be

started; see paragraph 6.14 " Test for verification of the correct insertion of the needle probe".

5.1

If the test is completed successfully, the cycle will be started.

5.2

If the test is not completed successfully, the buzzer will be activated, the device will display the

indication “ALARM San” and the cycle will be stopped.

Press and release a key to silence the buzzer.

During blast chilling the device displays the temperature detected by the needle probe, the cabinet temperature and

the time passed since the start of blast chilling.

Operate as indicated to stop the cycle:

6.

Press and hold the START/STOP key 3 s.

When the temperature detected by the needle probe reaches the blast chilling end temperature, it means that blast

chilling has been completed and the device will automatically pass to maintenance.

During maintenance the the blast chilling end temperature also establishes the work set-point during maintenance.

On expiry of the duration of maintenance the device automatically passes to storage.

Parameter r11 establishes the work set-point during storage.