14 alarms, 1 alarms – EVCO EVFTFT818P7U Installer manual User Manual

Page 79

Advertising
background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 79 of 94

14

ALARMS

14.1

Alarms

The following table illustrates the meaning of the alarm codes.

Code

Meaning

tiM

Temperature-controlled blast chilling or deep freezing not concluded within maximum duration alarm

(HACCP alarm).

Solutions:

-

check the value of parameters r5 and r6 and AA.

Main consequences:

-

the device will memorise the alarm

-

the alarm output will be activated.

AL

Minimum temperature alarm.

Solutions:

-

check the temperature of the cabinet

-

check the value of parameters A1 and A2.

Main consequences:

-

the alarm output will be activated.

AH

Maximum temperature alarm (HACCP alarm).

Solutions:

-

check the temperature of the cabinet

-

check the value of parameters A4 and A5.

Main consequences:

-

the device will memorise the alarm

-

the alarm output will be activated.

id

Door open alarm

Solutions:

-

check the door conditions

-

check the value of parameters i0 and i1.

Main consequences:

-

the effect established with parameter i0

-

the alarm output will be activated.

HP

High pressure alarm.

Solutions:

-

check the conditions of the high pressure input

-

check the value of parameters i5 and i6.

Main consequences:

-

the effect established with parameter i5

-

the alarm output will be activated.

Advertising