EVCO EVFTFT818P7U Installer manual User Manual

Page 89

Advertising
background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 89 of 94

Overvoltage category:

integrated control.

Clock:

incorporated (with condenser).

Battery autonomy in the event of a power-cut: 24 h with battery

fully charged.

Battery charging time: 2 min (the battery is charged by the device

power supply).

Signal buzzer and alarm:

incorporated.

Analogue inputs:

6 inputs (cabinet probe, “multipoint” needle probe with up to three

sensors, evaporator probe and condenser probe) can be set via

configuration parameter for PTC/NTC probes.

PTC type analogue inputs (990 Ω @ 25°C, 77°F)

Type of sensor:

KTY 81-121.

Field of measurement:

from

-50

to

150°C

(from -58 to 302°F).

Resolution:

1 °C (1 °F).

Protection:

none.

NTC type analogue inputs (10K Ω @ 25°C, 77°F)

Type of sensor:

ß3435.

Field of measurement:

from

-40

to

105°C

(from -40 to 220 °F).

Resolution:

1 °C (1 °F).

Protection:

none.

Digital inputs:

4 inputs (door micro switch, high pressure, low pressure and

compressor circuit breaker protection), which can be set via

configuration parameter due to normally open contact/normally

closed contact (potential-free contact, 5 VDC, 2 mA)

Digital inputs

Power supply:

none.

Protection:

none.

Displays:

320 x 240 pixel (3.5 inch) colour TFT graphics display

Analogue outputs:

1 PWM output for management of the evaporator fan.