12.4

Download of the information relative to the HACCP

alarms

To make the download of the information relative to the HACCP alarms operate as follows:

1.

Make sure the device is in the “stand-by” status.

2.

Insert an USB peripheral in the USB serial port.

3.

Press and release the

key (1), the

key (2) or the

key (3) to set the day and the time from which the

information must begin, then press and release the START / STOP key (4): it will automatically be started the

writing (into the peripheral) of a CSV (Comma Separated Values) document by name (for example)

“log247n00001.csv” (containing information relative to the HACCP alarms); the writing procedure can take

some minutes.

The name of the CSV document is made (with reference to the example) as follows:

-

“log”: fix field

-

“247”: value of paramater LA (device address)

-

“n”: fix field

-

“00001”: progressive number of downloads of the information relative to the HACCP alarms.

To set the kind of information to be downloadedoperate as follows:

3.1

Make sure the device is in the “on” status.

3.2

Make sure the keyboard is not locked and no procedure is in progress.

3.3

Press and release the HOME key (1), press and release the MENU key (2), then press and release

the

key (3) to select “HACCP ALARMS”.