EVCO EVFTFT818P7U Installer manual User Manual

Page 40

Advertising
background image

EVCO S.p.A.

EVFTFT818 | Installer manual ver. 2.1 | Code 144FTFT818E214

page 40 of 94

During soft deep freezing phase, the device displays the residual deep freezing time, the temperature of the cabinet,

the name of the program (if envisioned) and the time passed from the start of deep freezing.

Operate as indicated to stop the cycle:

6.

Press and hold the START/STOP key 3 s.

The successive parameters establish the following values:

-

parameter r7 establishes the work set-point during the deep freezing soft phase.

-

parameter r14 establishes deep freezing soft phase duration.

On expiry of the soft deep freezing phase duration, the device automatically passes to deep freezing.

During deep freezing the device displays the residual deep freezing time, the temperature of the cabinet, the name of

the program (if envisioned) and the time passed from the start of deep freezing.

The successive parameters establish the following values:

-

parameter r2 establishes deep freezing duration

-

parameter r8 establishes the work set-point during deep freezing.

On expiry of the deep freezing duration, the device automatically passes to storage mode and the buzzer is activated

for the time period established with parameter AA.

Press and release a key to silence the buzzer.

During storage the device displays the temperature of the cabinet, the program name (if envisioned) and the duration

of deep freezing.

Parameter r11 establishes the work set-point during storage.

Advertising