Digital outputs:

8 outputs (electromechanical relays):

-

1 x 16 A res. output @ 250 VAC SPST type (K1) for

compressor management

-

6 x 8 A res. outputs @ 250 VAC of which five SPST type for

managing defrosting (K2), the evaporator fan (K3), the

condenser fan (K4), cabinet light or UV light (K7), the pump

down valve or alarm output (K8) and one SPDT type for

management of the door heating elements (K5)

-

1 x 16 A res. output @ 250 VAC SPDT type (K6) for heating

management of the needle probe.

Type of actions and complementary

features:

1C.

Communication port:

2 ports:

-

1 RS-48 serial port with MODBUS communication protocol

-

1 USB serial port (only available in the model

EVFTFT818P7U).