Door Sensor Type: Select the type of door sensor installed at the device. The most common type is NC (nor-

mally close). Door sensor is a must-have component if you want to monitor door activities. It responds to

standalone device or Ingress all the time to report door status.

Configurations to apply to door with standalone device only

Full Access Device: Important setup if you apply Time Zone settings to the door. Select exit device to become

full access device. Full access device ignores time zone settings. Users can verify at the device to leave

the zone anytime.
Entry Device: Defines if the device is used for In or Out transactions. For example, all records from an In de-

vice will be recorded as In while records from the other device at the same door will be recorded as Out.
Alarm Delay: Change to set the duration before triggering alarm during emergency. Set to 0 for the device

to trigger alarm immediately during emergency.
Error Times To Alarm: To set the maximum times of failed verification before device triggers alarm. This is to

alert the unauthorized person to not tamper with the device.
Duress Alarm 1:1 Trigger
Duress Alarm 1:N Trigger
Duress Alarm Password Trigger
During emergency users can verify at the device to trigger duress alarm to alert others. For example,

robbers force user to verify to unlock the door to access into the zone. User can verify at device to trigger

alarm to alert the users inside the zone.
Activate one of the above options as the duress alarm trigger method. If you are using fingerprint verifi-

cation to gain access during normal days, activate Duress Alarm Password Trigger. The device will then

trigger the alarm when you insert your password. Refer to the device’s user guide for details on how to

enroll fingerprint or password to trigger duress alarm.
Duress Alarm Delay: Change to set duration before alarm is triggered during duress scenario. Set 0 and device

will trigger alarm immediately during duress scenario.
Door Sensor Type: Select the type of door sensor installed at the device. The most general type is NC. Door

sensor is an important component to monitor door activities. In case of door force open or door remain

open, the door sensor reports it to the device. You can see the status of door under the Monitoring page

in Ingress. Select None if you did not install door sensor, but you can no longer monitor the activities

from this door.

Configurations to apply to door with Ingress only

Permanent Door Open/Close Holiday Time Zone: Select to follow time range settings to allow free access (without

verification at the device) to the zone during holiday. Requires setup of Holiday list and Permanent Door

Open Close Holiday Time Zone. Leave this blank to ignore this feature.
Punch Interval: Set the time duration between 1st and 2nd verification from the same user, for example 10s.

Ingressus will not grant access to the user if he/she verifies twice within 10s from any slave devices.
Verify Mode: To select combination of verification to gain access.
Duress Password: Same as Duress Alarm Password Trigger.
Emergency Password: During emergency, users can enter an emergency password to unlock any door (con-

trolled by Ingressus) at anytime. Time zone or access control settings will not affect it. This is normally

done by the administrator.
Door sensor delay: Set the time duration before Ingressus triggers the alarm if door remains open.
Close and Reverse State: Activate this if you want EM lock or dropbolt to lock immediately once door closes.

You must install door sensor together with the door lock. When the door sensor touches each other, In-

gressus receives the signal and activates the door lock system immediately. This overrides the Door Open
Duration settings and can avoid unauthorized access or tailgating incident.