Comtech EF Data CRS-170A User Manual

Page 108

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–38

5.6.2.3 Non-IP Data Interface Kit and Connection Examples

While different data interface cards may be installed into both PIIC (Plug-In

Interface Card) slots, only one data interface type is operable at a given time. The

data interface combinations allowable in the CDM-760/-750 chassis PIIC Slots 1

and 2 are as follows:

PIIC Slot 1

PIIC Slot 2

G.703 E3/T3

None

None

G.703 E3/T3

You will need separate cabling kits for each CDM-760/-750 non-IP data interface configuration.

Each user data interface requires one interface kit per 1:1 modem pair. For example, Figure 5-32

in Sect. 5.6.2.3.1 identifies the interface kit and its quantities that you will use for the G.703 PIIC

data interface.

Figure 5-31 shows the block diagram that is typical for the kits shown in this section. Note that

this diagram does not apply to the default Gigabit Ethernet data interface configuration (Figure

5-29), which requires user-provided Ethernet cables and Layer 2 switches.

Figure 5-31. CDM-760/-750 Block Diagram – UserModemSwitchTraffic

Advertising