4 summary of specifications – Comtech EF Data CRS-170A User Manual

Page 39

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Introduction

Revision 13

1–19

1.4 Summary of Specifications

Equipment Type

L-Band 1:1 Redundancy Switch

Manufacturer

Comtech EF Data, Tempe, Arizona

Supported Comtech EF Data Modems

CDM-625A Advanced Satellite Modem with/without optional IP

Packet Processor

CDM-625 Advanced Satellite Modem with/without optional IP Packet

Processor

CDM-850 Remote Router

CDM-840 Remote Router

CDM-760 Advanced High-Speed Trunking Modem

CDM-750 Advanced High-Speed Trunking Modem

CDM-570AL L-Band Satellite Modem with/without optional IP Packet

Processor

CDM-570L L-Band Satellite Modem with/without optional IP Module

CDM-710GL L-Band High-Speed Satellite Modem

CDM-710 L-Band Broadcast Satellite Modem

CDM-700 L-Band Satellite Modem

CDM-600L (CLM-9600L) with CRS-150 1:1 Data Switch

SDM-300L3 with SMS-301 1:1 Data Switch

Operating Modes

Fully automatic under control of supporting 1:1 switch.

Manual under control of supporting 1:1 switch.

Architecture

Full bridging architecture when supported by CRS-150, or SMS-301

data switching and control, with configuration synchronization.

Tx redundancy supports all BUC interface signals (RF, 10 MHz

reference, FSK communications, and power supply)

Rx IF signal fed to both Online and Backup units. Rx switching

supports all LNB interface signals (RF, 10 MHz reference, and power

supply.)

Switch Conditions

Tx/Rx switching follows state of supporting data switching via control input

from data switch.

IF Switching / Splitting

Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF

isolation)

Rx IF: Passive power splitting (7 dB max loss)

BUC Power Switching

Switched by power relay (60VDC max, 4A max)

BUC 10 MHz Reference Switching

Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)

BUC FSK Comms Switching

Switched by relay (70dB min ON/OFF isolation)

LNB Power Switching

Switched by power relay (28 VDC max)

LNB 10 MHz Reference Switching

Switched by relay (1 dB max loss)

Tx-Rx Isolation

90dB min, 950-2250 MHz

IF Impedance

Optimized for 50Ω (> 10 dB return loss on external IF ports)

IF Connectors

50Ω Type N Female

Advertising