4 summary of specifications – Comtech EF Data CRS-170A User Manual

Page 39

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Introduction

Revision 13

1–19

1.4 Summary of Specifications

Equipment Type

L-Band 1:1 Redundancy Switch

Manufacturer

Comtech EF Data, Tempe, Arizona

Supported Comtech EF Data Modems

•

CDM-625A Advanced Satellite Modem with/without optional IP

Packet Processor

•

CDM-625 Advanced Satellite Modem with/without optional IP Packet

Processor

•

CDM-850 Remote Router

•

CDM-840 Remote Router

•

CDM-760 Advanced High-Speed Trunking Modem

•

CDM-750 Advanced High-Speed Trunking Modem

•

CDM-570AL L-Band Satellite Modem with/without optional IP Packet

Processor

•

CDM-570L L-Band Satellite Modem with/without optional IP Module

•

CDM-710GL L-Band High-Speed Satellite Modem

•

CDM-710 L-Band Broadcast Satellite Modem

•

CDM-700 L-Band Satellite Modem

•

CDM-600L (CLM-9600L) with CRS-150 1:1 Data Switch

•

SDM-300L3 with SMS-301 1:1 Data Switch

Operating Modes

•

Fully automatic under control of supporting 1:1 switch.

•

Manual under control of supporting 1:1 switch.

Architecture

•

Full bridging architecture when supported by CRS-150, or SMS-301

data switching and control, with configuration synchronization.

•

Tx redundancy supports all BUC interface signals (RF, 10 MHz

reference, FSK communications, and power supply)

•

Rx IF signal fed to both Online and Backup units. Rx switching

supports all LNB interface signals (RF, 10 MHz reference, and power

supply.)

Switch Conditions

Tx/Rx switching follows state of supporting data switching via control input

from data switch.

IF Switching / Splitting

•

Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF

isolation)

•

Rx IF: Passive power splitting (7 dB max loss)

BUC Power Switching

Switched by power relay (60VDC max, 4A max)

BUC 10 MHz Reference Switching

Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)

BUC FSK Comms Switching

Switched by relay (70dB min ON/OFF isolation)

LNB Power Switching

Switched by power relay (28 VDC max)

LNB 10 MHz Reference Switching

Switched by relay (1 dB max loss)

Tx-Rx Isolation

90dB min, 950-2250 MHz

IF Impedance

Optimized for 50Ω (> 10 dB return loss on external IF ports)

IF Connectors

50Ω Type N Female

Advertising