CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Installation

Revision 13

2–2

2.2 Mount the Switch

The CRS-170A switch module’s small size and weight allow it to be freestanding. You may

choose to let the module hang freely, supported only by the interfacing cables.

Comtech EF Data KT/11708 Switch Mounting Kit

CEFD P/N

Qty

Description

FP/PN11575-1

1

Switch Mounting Panel

HW/6-32X3/8FLT

4

#6-32 x 3/8” LG SS Flat Head Machine Screw

Figure 2-1. Optional KT/11708 Switch Mounting Kit

You may also mount the module into a 1RU space at the front or rear of the rack enclosure that

houses the modems. The optional Comtech EF Data KT/11708 Mounting Panel Kit is available for

this purpose. As shown in Figure 2-1, the module can be installed vertically or horizontally to the

kit’s slotted mounting panel. User-supplied screws are then required to secure the panel to the

rack enclosure threaded mounting rails.

CAUTION – PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be

connected to the protective earth connection at all times. It is therefore imperative

that the Switch and its paired modems are properly grounded – using the ground stud

provided on the Switch antenna side panel and the ground studs located on the

modem rear panels – during installation, configuration, and operation.