CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–69

Figure 5-54 shows the block diagram typical for the kits shown in Sects. 5.10.2.1.1 through

5.10.2.1.3. For example, Sect. 5.10.2.1.1 identifies the interface kit used with the CDI-10 Dual

G.703 E3/T3/STS-1 and CDI-60 HSSI data interfaces.

With the exception of the CDI-70 Gigabit Ethernet data interface configuration shown in Sect.

5.10.2.2, which uses user-provided Ethernet cables and Layer 2 Switch, you must use one

interface kit per 1:1 modem pair for each interface (see examples for specific quantities).

5.10.2.1.1 Dual G.703 E3/T3/STS-1 75 Data Interface (CDI-10) Kit

KT/12582 and HSSI Data Interface (CDI-60) Kit KT/12586

Figure 5-55 shows an example of a CDM-700 1:1 modem configuration with the CDI-10 Dual

G.703 Data Interface installed in Slot 1, and the CDI-60 HSSI Data Interface installed in Slot 2.

The figure depicts installation of one KT/12582 Dual G.703 Interface Kit (each kit can supply one

or two CDI-10 interfaces), and one KT/12586 HSSI Interface Kit.













KT/12582 G.703 (CDI-10) 75 Interface Kit

CEFD Part No.

Qty Description

CA/BNC75OHM

8

Cable – IF BNC, 75Ω, 1’

RF/SA32KC-IN/OUT

4

Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC

KT/12586 HSSI (CDI-60) Interface Kit

CEFD Part No.

Qty Description

PP/SC3523

1

Cable - RoHS-Compliant, HSSI ‘Y’ Splitter, (2X) HD-50M  HD-50F, 3”

Figure 5-55. CDM-700 CDI-10 G.703 E3/T3/STS-1, CDI-60 HSSI 1:1 Example