Comtech EF Data CRS-170A User Manual

Page 122

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–52

5.8.2 Modem-to-User Data Interface Kit and Connection Examples

In addition to the basic Modem-to-Switch cabling shown previously, a number of data interface

configuration kits are available for use with the CDM-710GL High-Speed Satellite Modem.

Separate cabling kits are needed for these CDM-710GL data interfaces.

While different data interface cards may be installed into both Interface slots, only

one data interface type is operable at a given time. The data interface

combinations allowable in the CDM-710GL chassis Interface Slots 1 and 2 are as

follows:

Interface Slot 1

Interface Slot 2

Single G.703 (CDI-10-1)

None

HSSI (CDI-60)

None

None

GigE (CDI-70)

5.8.2.1 Modem-to-User Non-IP Data Interface Kit and Connection

Examples

Figure 5-42. CDM-710GL Block Diagram – UserModemSwitchTraffic

Figure 5-42 shows the block diagram typical for the kits shown in Sects. 5.8.2.1.1 and Sect.

5.8.2.1.2. For example, Sect. 5.8.2.1.1 identifies the interface kit used with the CDI-10-1 Single

G.703 data interface.

With the exception of the CDI-70 Gigabit Ethernet data interface configuration shown in Sect.

5.8.2.2, which uses user-provided Ethernet cables and Layer 2 Switch, you must use one

interface kit per 1:1 modem pair for each interface (see examples for specific quantities).