1 cdm-570l/al non-ip redundancy configuration – Comtech EF Data CRS-170A User Manual

Page 61

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Modem and Switch Configuration

Revision 13

4–13

4.5.1 CDM-570L/AL Non-IP Redundancy Configuration

Do these steps for setup of CDM-570L/AL modems for 1:1 Redundancy, when the terrestrial

data type is non-Ethernet (i.e. RS422, G.703).

Step

Task

1

Enable 1:1 Redundancy on both modems:

From the CLI Main Menu, press ‘E’ to open the 1:1 Redundancy Configuration page.

o

Press ‘R’ to toggle 1:1 Redundancy as [Enabled].

o

Press ‘S’ to ““Save Parameters to permanent storage”.

Alternately, using the HTTP (Web Server) Interface ‘REDUNDANCY’ page:


o

Use the drop-down list in the 1:1 Redundancy Control section of this page to select

Enabled.

o

Click [Submit] to save.

If you submit any changes to this web page when the CDM-570AL optional IP

Packet Processor is INSTALLED, you must also open the ‘Admin | Pap Save’

page and immediately click [Save PaP Parameters].

2

Connect all cables to the modems and the CRS-170A. This includes the control cable, IF cable and

data ‘Y’cables.

Chapter 5. CABLES AND CONNECTIONS

Advertising