CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Modem and Switch Configuration

Revision 13

4–9

4.4 CDM-760 or CDM-750 Operation in 1:1 Redundancy

CDM-760 Advanced High-Speed Trunking Modem Installation and Operation

Manual (CEFD P/N MN-CDM760)

CDM-750 Advanced High-Speed Trunking Modem Installation and Operation

Manual (CEFD P/N MN-CDM750)

The CDM-760 and CDM-750 Advanced High-Speed Trunking Modems automatically detect

connection to a 1:1 redundancy system.

Typical for either product, with both modems automatically configured for 1:1 operation, the

online modem keeps the offline modem updated as online modem configuration changes

occur.

You can also manually ‘force’ backup of the online modem. Use the modem front panel to

select the SELECT: Utility 1:1 screen:

Press ENTER key to force Unit into
Standby (1:1 only)

If this unit is currently the online unit in a 1:1 redundant pair, press ENTER to force the unit to

switch to standby mode.