7 cabling to the cdm-570l or cdm-570al – Comtech EF Data CRS-170A User Manual

Page 111

Advertising
background image

CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–41

5.7 Cabling to the CDM-570L or CDM-570AL

1)

For information on the CDM-570L/AL’s 1:1 auto-enable functionality, see:

Chapter 4. MODEM

AND

SWITCH

CONFIGURATION

CDM-570A/CDM-570AL/CDMR-570AL Satellite Modem Installation and

Operation Manual (CEFD P/N MN-CDM570A)

CDM-570/CDM-570L/CDMR-570L Satellite Modem Installation and

Operation Manual (CEFD P/N MN/CDM570L.IOM)

2)

For detailed information about the cables and cable assemblies specified in this

section, see Appendix A. CABLE DRAWINGS.

5.7.1 CRS-170ACDM-570L/AL Interface Connections Using 1:1

Redundancy Kit KT/10860-1

You must use the items provided in the Comtech EF Data KT/10860-1 1:1 Redundancy Kit for all

possible CDM-570L/AL data interface configurations:

KT/10860-1 1:1 Redundancy Kit – Interface Cabling Reference (CRS-170A CDM-570L/AL)

CEFD Part No. Qty/Kit

(REF) Description

Used For

Ch. 5

Fig

PL/10129-1

1

CRS-170A Switch – Top Assembly

1:1 Redundancy

5-32

5-33

CA/WR9378-4

2

Control Cable – Universal, DB-9M  DB-9M, 4’

Modem  Switch

Control

5-32

CA/RF10453-4

4

RoHS-Compliant Cable – IF (Tx/Rx),

50Ω Type ‘N’, 4’

Modem  Switch IF

Interface

5-33

CA/RB10461-1

1

Cable – 1:1 Y-Splitter, (2X) DB-25M  DB-25F

EIA-422/232

Interface

5-35

CA/WR10522-1

1

Cable – 1:1 Y-Splitter, (2X) DB-15M  DB-15F

G.703 Balanced

5-36

KT/10553-1

1

G.703 Unbalanced Interface Kit containing:

(Qty 4) CA/BNC75OHM Cable – IF BNC, 1’

(Qty 2) CN/BNC-Tee-JPJ T-Adapter, 50Ω BNC

G.703 Unbalanced

5-37

Figure 5-33 and Figure 5-34 show how to connect a pair of CDM-570L/AL modems together with

the CRS-170A L-Band 1:1 Redundancy Switch module; the table that accompanies each figure

lists all cables and components needed from the KT/10860-1 for this initial switch-to-modem

setup.

Advertising