CRS-170A L-Band 1:1 Redundancy Switch

MN/CRS170A.IOM

Cables and Connections

Revision 13

5–4

5.2.1 KT-0000160 Redundancy Control / IF Interface Cabling Kit

(CDM-625/A, CDM-850, CDM-840, CDM-760, CDM-750)

KT-0000160 1:1 Redundancy Control / IF Interface Cabling Kit

CEFD Part No.

Qty Description

Used For

PL/10129-1

1 CRS-170A Switch – Top Assembly

1:1 Redundancy

CA/WR9378-4*

2 Control Cable – Universal, DB-9M  DB-9M, 4’

Modem  Switch Control

CA/RF10453-4

4 RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’ Modem  Switch IF

Interface

* Alternate Cabling Note: CEFD Universal Control Cable CA/WR9378-8 (DB-9M

DB-9M, 8’), sold separately, is available for use in place of CA/WR9378-4

5.2.2 KT/12551 Redundancy Control / IF Interface Cabling Kit

(CDM-710GL, CDM-710, CDM-700)

KT/12551 1:1 Redundancy Control / IF Interface Cabling Kit

CEFD Part No.

Qty Description

Used For

PL/10129-1

1 CRS-170A Switch – Top Assembly

1:1 Redundancy

CA/WR12135-1*

2 Control Cable – Universal, DB-9M  DB-9M, 4’

CDM-710GL  Switch

Control

CA/RF10453-4

4 RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’ CDM-710GL  Switch IF

Interface

* Alternate Cabling Notes:

1)

To provide User access to modem “Fault Summary Relay,” Control ‘Y’ Cable

CA/WR13011-4 (DB-15F DB-9M [4’], DB-9M [6”]), sold separately, is

available for use in place of the CA/WR12135-1 cable.

2)

Control Cable CA/WR12135-1 will mute the Offline modem’s Tx IF. If this is not

desired, then an alternate cable, Control Cable CA-0000187 (DB-15F DB-9M,

6’), sold separately, is available for use in place of the CA/WR12135-1 cable