Nitrogen, Ht4001 without slave, Pac620 torch – standard consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 114: Stainless steel – nitrogen plasma

Advertising
background image

11-96

HT4001

Instruction Manual

5-23

Notes:

• Minimum N

2

inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.

• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N

2

flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.

• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you are

cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.

HT4001 without Slave

PAC620 Torch – Standard Consumables

Stainless Steel – Nitrogen Plasma

Retaining Cap

020579 (Vect)

020246 (Vesp)

Nozzle

020089

(.120 in/3 mm)

020084

(.166 in/4.2 mm)

Swirl Ring

020039 (cw)

020042 (ccw)

Electrode

020082

Water Tube – Standard

020990

120466 – CE (Vect)
120467 – CE (Vesp)

E

N

G

L

I

S

H

M

E

T

R

I

C

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(in)

(mm)

(%)

(%)

(%)

(in)

(mm)

(ipm)

(mm/min)

.035

.889

30

30

45

125

260

1/8

3

450

11430

.075

1.91

30

30

45

130

260

1/8

3

300

7620

1/8

3.18

30

30

45

135

260

1/8

3

200

5080

1/4

6.35

30

30

45

145

260

1/8

3

150

3810

3/8

9.53

45

45

62

150

380

3/16

5

125

3170

1/2

12.7

45

45

62

155

400

3/16

5

100

2540

3/4

19.1

45

45

62

160

400

3/16

5

50

1270

1

25.4

45

45

62

165

400

1/4

6

30

760

1-1/2

38.1

45

45

62

185

400

1/4

6

20

510

2

50.8

45

45

62

200

400

1/4

6

12

300

.166"

400A max.

Arc

Current

(A)

Torch

Standoff

Travel Speed

.120"

260A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(mm)

(%)

(%)

(%)

(mm)

(mm/min)

3 mm

260A max.

6

30

30

45

145

260

3

3950

10

45

45

62

150

380

5

3070

12

45

45

62

155

400

5

2680

15

45

45

62

160

400

5

2080

20

45

45

62

160

400

5-6

1200

25

45

45

62

165

400

6

790

35

45

45

62

180

400

6

570

50

45

45

62

200

400

6

310

Arc

Current

(A)

Torch Standoff

Travel Speed

4.2 mm

400A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)

Advertising