SPECIFICATIONS

1-98

HT4001

Instruction Manual

2-5

Specifications

System Requirements

Power Requirements:
Refer to HT4001 Power Supply specifications below:

Gas Requirements:
Plasma Gas Types ..............................................Oxygen (O

2

), Nitrogen (N

2

)

Gas Quality

Oxygen .............................................................99.5%
Nitrogen............................................................99.995%

Oxygen Gas Inlet Pressure .................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar)
Nitrogen Gas Inlet Pressure ................................150 psi +/- 10 psi (10.3 bar +/- 0.7 bar)
Air Gas Inlet Pressure (for Wtr Muffler and IHS) ..120 psi (8.3 bar)

Water Requirements:
Water Flow ...........................................................0.5 gpm (1.9 l/m) to water chiller

2.5 gpm (9.5 l/m) to RHF console

Water Inlet Pressure ............................................35 psi (2.4 bar) to water chiller

150 psi (10.3 bar) to RHF console

HT4001 Power Supply – with Slave

Maximum OCV (U

0

)..............................................400 VDC

Maximum Output Current (I

2

) ...............................760 A

Output Voltage (U

2

) .............................................80-200 VDC

Duty Cycle Rating (X) ..........................................100% @ 40°C at 760 A and 200 V
Ambient Temperatures/Duty Cycle.......................Power supplies will operate between +14° and

104°F (-10° and +40°C).
Power supplies operated in an ambient temperature
above 86°F (30°C) may show some decrease in
duty cycle.

Cooling .................................................................Forced Air (Class F)

See instruction manual 800410: H401 & H601 for further specifications on the H401 slave power supply.

HT4001 Power Supply

Maximum OCV (U

0

)..............................................361 VDC

Maximum Output Current (I

2

) ...............................400 A

Output Voltage (U

2

) .............................................80-200 VDC

Duty Cycle Rating (X) ..........................................100% @ 40°C at 400 A and 200 V
Ambient Temperatures/Duty Cycle.......................Power supplies will operate between +14° and

104°F (-10° and +40°C).
Power supplies operated in an ambient temperature
above 86°F (30°C) may show some decrease in
duty cycle.

Power Factor (cos

ϕ)

.............................................0.94

Cooling .................................................................Forced Air (Class F)