INSTALLATION

5-00

4-12

HT4001

Instruction Manual

Power Supply Connections (cont.)

Machine Interface I/O Cable – PS to Machine Interface

PS END

MACH. END

SCKT

COLOR

LUG

DESCRIPTION AND COMMENTS

1

Wht

87

Hold (12VDC) Signal. Synchronizes starting of 2 or more systems. Closed=ON; Open=OFF

5

Blk

86

Hold - Common

10

Shield

Cut

Hold - Shield

2

Yel

173

Initial Height (12VDC) Signal. Closed=OFF ; Open=ON

6

Blk

174

Initial Height - Common

11

Shield

Cut

Initial Height - Shield.

3

Brn

171

Auto Height (12VDC) Signal. Closed=OFF; Open=ON or Corner (12VDC)

7

Blk

172

Auto Height - Common

12

Shield

Cut

Auto Height - Shield

4

Orange

135

Remote On/Off - See note on next page

8

Black

136

Remote On/Off - See note on next page

13

Shield

Cut

Remote On/Off - Shield

9

Blu

82

Plasma Start (24VAC) - Signal. Close=Start

15

Blk

83

Plasma Start - Signal.

14

Shield

Cut

Plasma Start - Shield.

22

Red

77

Upper Limit Switch, Hot. Normally closed. Open when fully retracted.

21

Wht

76

Upper Limit Switch, Neutral.

20

Shield

Cut

Upper Limit Switch, Shield.

28

Yel

80

Plasma Emergency Stop (24VAC) Signal. Closed =stop.

33

Red

81

Plasma Emergency Stop - Signal

27

Shield

Cut

Plasma Emergency Stop - Shld

34

Red

169

†Down Relay, Load (Solid state, rated to switch 24 to 120VAC, 1amp. DC relay optional) Closed=Down

29

Blk

170

Down Relay, Line

23

Shield

Cut

Down Relay, Shield

35

Grn

167

†Up Relay, Load (Solid state, rated to switch 24 to 120VAC, 1amp. DC relay optional) Closed=Up

30

Blk

168

Up Relay, Line

24

Shield

Cut

Up Relay, Shield

36

Red

84

†*Arc Xfer Output - Signal Contact closes after arc transfer and time delay. Dry contact relay.

31

Blu

85

*Arc Xfer Output - Signal

25

Shield

Cut

*Arc Xfer Output - Shield

37

Red

79

**Arc Voltage Isolated + Divided (1/100) Signal

32

Grn

78

**Arc Voltage Isolated + Divided (1/100) Sig

26

Shield

**Arc Voltage Isolated + Divided (1/100),Shld

7

PS End

Notes:

* Note on the µP PCB that resistor R150 and capacitor C78 are connected in series across the contacts. In some cases one lead of

R150 must be cut from the control PC board as the R-C circuit may provide enough current flow to maintain machine motion input to
cutting machine.

** Note on the µP PCB that resistor R155 and capacitor C79 are connected in series across the contacts. In some cases one lead of

R155 must be cut from the control PC board as the R-C circuit may provide enough current flow to maintain machine motion input to
cutting machine.

Signals are AC relays. DC relays are available as an option from Hypertherm by ordering kit: 128404

1X6

WARNING

When installing or servicing the HT4001, AC or DC line voltages may be present on the UP, DOWN and
TRANSFER signals even if the power supply line disconnect switch is OFF. Make certain that all line
disconnect switches relating to the HT4001 system are OFF during installation and when servicing.

Part No.

Length

023892

25 ft (7.5 m)

023893

50 ft (15 m)

023894

75 ft (23 m)

Part No.

Length

023895

100 ft (30.5 m)

023896

150 ft (46 m)

023897

200 ft (61 m)