MAINTENANCE

6-98

HT4001

Instruction Manual

6-25

Note:

In all Relay Board Figures, LED ON =

LED OFF =

Figure 6-5

Relay Board PCB4 in O

2

Test Preflow

RHF Inj. Wtr
(SV6 in RHF Csl)

Plasma OFF
(SV5 near torch)

Preflow
(SV2/SV3 in Gas Csl)

Plasma Preflow
(SV4B in MV Csl)

O2 Cutflow
(SV1A in Gas Csl)

+ 12 VDC

Output
Enable

Relay Board LED Status

Test Preflow Mode – O

2

Figure 6-6

Relay Board PCB4 in N

2

Test Preflow

RHF Inj. Wtr
(SV6 in RHF Csl)

Plasma OFF
(SV5 near torch)

Preflow
(SV2/SV3 in Gas Csl.)

+ 12 VDC

Output
Enable

Plasma N

2

/O

2

(SV1B in Gas Csl)

Plasma Preflow
(SV4B in MV Csl)

Relay Board LED Status

Test Preflow Mode – N

2

Advertising