MAINTENANCE

16

HT4001

Instruction Manual

6-3

Routine Maintenance

The HT4001 system is designed to require little regular maintenance under normal use. The following
maintenance checks, are suggested to keep your system in top running condition.

Torch and Torch Leads

(See also Torch Coolant Draining at the end of this section)

Inspection

Inspect the torch and torch leads on a routine basis.

• The torch consumable parts and torch main body should always be inspected prior to cutting. Worn or

damaged parts can cause gas and water leaks which can affect the cut quality. Check for pitting and burn
marks on the consumable parts and replace, if necessary. See Changing Consumable Parts in Section 5.

• Ensure that all connections are tight, but do not overtighten.

• The torch leads should be checked occasionally for cracking and damage.

Power Supplies

Inspection

Inspect the power supplies on a routine basis

• Check the exterior for any damage. If there is damage, ensure it does not affect safe operation of the

power supply.

• Remove covers and inspect the interior. Check wiring harnesses and connections for wear and damage.

Check for loose connections, and look for areas of discoloration due to overheating.

• Inspect the contacts on the contactor every 2 months. Worn contacts can be replaced by ordering kit

129972 for all voltages except 200V or 129973 for 200V power supplies.

Cleaning

Cleaning the power supply periodically is necessary to keep dust and foreign matter from inside the unit.

• Remove the covers and blow out the unit with compressed air. In an excessively dirty environment, clean

the power supply on a weekly basis.

Protecting Copper Surfaces

To protect copper surfaces in the injection water/torch coolant open loop, do the following twice a year:

1. Mix a 16 ounce container of corrosion inhibitor benzotriazole (128020) in the water chiller's 45 gallon water

reservoir.

2. Turn on the water chiller and run the pump for 2 hours. Do not start the power supply or attempt to cut with the

torch while recirculating the solution.

3. Turn water chiller off and leave power supply off for 8 hours.

4. Resume normal operating procedures.