Nitrogen, Ht4001 without slave, Pac620 torch – beveling consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 119: Aluminium – nitrogen plasma

Advertising
background image

11-96

5-28

HT4001

Instruction Manual

Notes:

• Minimum N

2

inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.

• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N

2

flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.

• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you are

cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.

HT4001 without Slave

PAC620 Torch – Beveling Consumables

Aluminium – Nitrogen Plasma

Retaining Cap

120390 (Vect)

120391 (Vesp)

Nozzle

120386

(.120 in/3 mm)

120387

(.166 in/4.2 mm)

Swirl Ring

020039 (cw)

020042 (ccw)

Electrode

020968

Water Tube – N

2

Bevel

020991

120470 – CE (Vect)
120471 – CE (Vesp)

E

N

G

L

I

S

H

M

E

T

R

I

C

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(in)

(mm)

(%)

(%)

(%)

(in)

(mm)

(ipm)

(mm/min)

.035

.889

30

30

45

120

240

1/8

3

520

13200

.075

1.91

30

30

45

125

240

1/8

3

345

8760

1/8

3.18

30

30

45

130

260

3/16

5

230

5840

1/4

6.35

30

30

45

140

260

1/4

6

170

4320

1/8

3.18

55

55

62

140

280

1/4

6

220

5590

1/4

6.35

55

55

62

150

320

1/4

6

165

4190

3/8

9.53

55

55

62

150

340

1/4

6

130

3300

1/2

12.7

55

55

62

150

360

1/4

8

110

2800

3/4

19.1

55

55

62

150

380

5/16

8

60

1520

1

25.4

55

55

62

165

380

3/8

10

35

890

.166"

400A max.

Arc

Current

(A)

Torch

Standoff

Travel Speed

.120"

260A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(mm)

(%)

(%)

(%)

(mm)

(mm/min)

3 mm

260A max.

6

30

30

45

140

260

6

4500

6

55

55

62

150

320

6

4340

8

55

55

62

150

340

6

3720

10

55

55

62

150

340

6

3220

12

55

55

62

150

360

6

2900

15

55

55

62

150

360

6-7

2330

20

55

55

62

155

380

8

1430

25

55

55

62

160

380

10

930

Arc

Current

(A)

Torch Standoff

Travel Speed

4.2 mm

400A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)

Advertising