INSTALLATION

4-97

4-6

HT4001

Instruction Manual

Part No.

Length

023136

20 ft (6 m)

023078

25 ft (7.5 m)

023101

30 ft (9 m)

023135

40 ft (12 m)

023079

50 ft (15 m)

Part No.

Length

023124

75 ft (23 m)

023080

100 ft (30.5 m)

023081

150 ft (46 m)

023316

180 ft (55 m)

023188

200 ft (61 m)

Nozzle Lead – PS to RHF Console
Pass the fork terminal end of the nozzle lead through the small bushing in the lower rear of the HT4001 power
supply and connect to the start circuit assembly as shown in Figure 4-4. Connect the ring terminal end of the
nozzle lead to the inductor coil in the RHF console. See pages 4-8 and 4-22 through 4-25 for remaining RHF
console connections.

Power Supply Connections

The circled numbers on the right-hand pages represent connection points for the corresponding numbered cables
and hoses on the left-hand pages. Any special instructions for installation are also explained on the left-hand
pages. The cable and hose part numbers in this section represent the most commonly used lengths. For
additional lengths, see Section 7 or call Hypertherm
.

Part No.

Length

123009

25 ft (7.5 m)

123010

50 ft (15 m)

123011

75 ft (23 m)

Part No.

Length

123012

100 ft (30.5 m)

123013

150 ft (46 m)

123014

200 ft (61 m)

1

2

3

4

Fork Terminal

Ring Terminal

Power Cables – Power Supply (PS) to Power Source
See Connecting the Power in the Pre-Installation section of this manual.

Negative Lead – PS to Remote High Frequency (RHF) Console
Pass the negative 2 lead through one of the 2" bushings in the lower rear of the HT4001 power supply and
connect to the lower bar (-) on the center bail rear as shown in Fig. 4-4. Connect the other end of the negative
lead securely to the cathode block in the RHF console. See part number information below under Positive
Lead – PS to Work Table

Positive Lead – PS to Work Table
Pass the positive 3 lead through one of the 2" bushings in the lower rear of the HT4001 power supply and
connect to the upper bar (+) on the center bail rear as shown in Fig. 4-4. Connect the other end of the lead
securely to the grounded work table.

Note:

Two positive and two negative leads needed when cutting with from 400-750 amps. See
Appendix A to connect H401 Slave to HT4001 power supply.

WARNING

All power must be turned OFF before performing installation!!