H401 slave modification – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 224

APPENDIX A
4-00
a-2
HT4001
Instruction Manual
H401 Slave Modification
A PC board assembly must be added to the stock H401 power supply so that it can interface as a slave for the
HT4001 system. Kit 128315 contains the necessary components to make this change:
Part No.
Description
Qty.
128315
Kit:H401/601 Slave
008340
Standoff:8-32 X 1/4 Hex X 1" Lg Al
4
075022
M/S:8-32 X 3/8 PH PAN SST
4
041366
PCB Assy:HT4001 Cur Set Pt
1
023136
Cable:4/0 1/2Lug 20'
2
123377
Cable:HT4001 Slave 25'
1
129375
Harness: Kit 128315
1
802930
FSB: Slave Calibration
1
Adding the Current Setpoint PCB to the H401 Slave – Fig. a-1
1. Remove both side panels and top panel to the H401 power supply.
2. Find the center wall of the H401 supply that supports the terminal strip.
3. Attach the Current Setpoint PCB to the center wall.
WARNING
Make all H401 power supply modifications before hooking up power cord.