OPERATION
5-6
HT4001
Instruction Manual
Controls and Indicators (cont.)
Digital Remote (DR) V/C Module (Fig. 5-4)
• VOLTAGE Adjust Pot
Adjusts the cutting arc voltage from 90 to 205 volts. Values are chosen from the Cut Charts and depend on
the type of metal to cut, and metal thickness.
• VOLTAGE LEDs
Displays cutting voltage.
• CURRENT Adjust Pot
Adjusts the cutting arc current from 90 to 800 amps. Values are chosen from the Cut Charts and depend on
the type of metal to cut, and metal thickness.
• CURRENT LEDs
Displays cutting current.
• UP / DOWN LEDs
Indicates that torch height is being adjusted up or down.
Figure 5-4
Digital Remote (DR) V/C Front Panel Controls and Indicators