INSTALLATION
4-98
4-36
HT4001
Instruction Manual
Optional Power Supply Connections
Hold cable – PS to Second HT4001 Power Supply
When using a multi-torch system, the hold cable interfaces the two HT4001 power supplies. Make
connections at TB3 on both supplies. TB3 is located on the inside rear wall of the HT4001 power supply.
PS1
PS2
END
COLOR
END
FUNCTION
86
Black
86
Hold signal
87
Red
87
Hold common
PE
Shield
GND
Hold shield
Slave Cable – PS to H401 or H601 Power Supply
Positive Lead – PS to H401 or H601 Power Supply
Negative Lead – PS to H401 or H601 Power Supply
Positive Lead – PS to Work Table (Additional lead needed when using slave)
Negative Lead – PS to RHF Console (Additional lead needed when using slave)
When using more than 400 amps of cutting current, a slave power supply must be used with the HT4001
power supply. See Appendix A for details.
29
30
31
32
33
34
Black
Red
GND
Black
Red
GND
Part No.
Length
023340
15 ft (4.5 m)
023341
25 ft (7.5 m)
023342
50 ft (15 m)
Part No.
Length
023343
100 ft (30.5 m)
023344
150 ft (46 m)