OPERATION

5-4

HT4001

Instruction Manual

Controls and Indicators (cont.)

Gas Console (Fig. 5-3)

PLASMA N

2

/O

2

Toggle Switch (S1)

Selects the use of either nitrogen or oxygen as the plasma cutting gas.

Test Preflow / Run / Test Cut Flow Toggle Switch (S2)

Test Preflow – Used when setting the plasma gas preflow flow rates on the flow meters as specified in the
Cut Charts. In this position the contactor is disabled.

N

2

(FM1) and O

2

(FM2) flow meters - In test preflow, indicate the percentage of plasma gas flow, nitrogen

or oxygen/nitrogen mix, required for pre-cut conditions.

N

2

Preflow (MV2) and O

2

Preflow (MV3) metering valves - Adjusts plasma gas preflow.

Test Cut Flow – Used when setting the plasma gas cut flow rate on the N

2

or O

2

flow meter for cutting

conditions as specified in the Cut Charts. In this position the contactor is disabled.

N

2

(FM1) or O

2

(FM2) flow meter – In test cut flow, indicates the percentage of plasma gas flow, oxygen or

nitrogen, required for cutting conditions.

PLASMA Cut Flow motor valve (MV1) (Activated by momentary switch) – Adjusts plasma gas test cut

flow.

Run – Enables the contactor and the subsequent firing of the arc after the gas flow rates have been set in
the Test Preflow and Test Cut Flow positions and the H

2

O Injection (torch water injection) as described

below has been set.

H

2

O Injection flow meter (FM3) – Indicates the percentage of injection water flow as indicated in the Cut

Charts.

H

2

O Injection metering valve (MV4) – Adjusts injection water flow as indicated in the Cut Charts.