Power Supply Connections (cont.)

Water Muffler Air Control Cable – PS to Water Muffler Air Control Box
See water muffler instruction manual IM173 for remaining connections to water muffler, and detailed
information on the water muffler system.

PS

WM AIR CNTRL

END (1X11)

COLOR

END (10X1)

SIGNAL

11

Wht

1

Water Muffler Hot

12

Black

2

AC Neutral

13

Red

3

Contactor Coil

14

Brown

4

Water Muffler Coil

6

Green

5

Ground

Water Muffler Pump Cable – PS to Water Muffler Pump
See water muffler instruction manual IM173 for remaining connections to water muffler, and detailed
information on the water muffler system.

PS
END (1X10)

COLOR

SIGNAL

2

Black

Water Muffler Coil

4

White

AC Neutral

3

Green

Ground

13

14

1x11

10x1

PS End

Air Control Box End

PS End

Water Muffler
Pump End

1X10

Part No.

Length

023866

50 ft (15 m)

023867

75 ft (23 m)

023868

100 ft (31 m)

Part No.

Length

023905

25 ft (7.5 m)

023906

50 ft (15 m)

023907

75 ft (23 m)

Part No.

Length

023908

100 ft (30.5 m)

023909

150 ft (46 m)

023910

200 ft (61 m)